37,80 €
Statt 54,00 €**
37,80 €
inkl. MwSt.
**Preis der gedruckten Ausgabe (Broschiertes Buch)
Sofort per Download lieferbar
payback
0 °P sammeln
37,80 €
Statt 54,00 €**
37,80 €
inkl. MwSt.
**Preis der gedruckten Ausgabe (Broschiertes Buch)
Sofort per Download lieferbar

Alle Infos zum eBook verschenken
payback
0 °P sammeln
Als Download kaufen
Statt 54,00 €****
37,80 €
inkl. MwSt.
**Preis der gedruckten Ausgabe (Broschiertes Buch)
Sofort per Download lieferbar
payback
0 °P sammeln
Jetzt verschenken
Statt 54,00 €****
37,80 €
inkl. MwSt.
**Preis der gedruckten Ausgabe (Broschiertes Buch)
Sofort per Download lieferbar

Alle Infos zum eBook verschenken
payback
0 °P sammeln
  • Format: PDF

In this work, a holistic approach is used to develop a multi-physical model of the Vanadium Redox Flow Battery on a system level. The model is validated with experimental data from three flow battery manufacturers and is then deployed in an extensive parameter study for designing a flow battery cell. Using finite element analysis (FEA), twenty-four different cell designs are derived, which vary in electrode area and the design of the electrolyte inlet and outlet supply channels. The performance of the designs is then simulated in a single-stack and a three-stack string system. The presented…mehr

  • Geräte: PC
  • ohne Kopierschutz
  • eBook Hilfe
  • Größe: 14.52MB
  • FamilySharing(5)
Produktbeschreibung
In this work, a holistic approach is used to develop a multi-physical model of the Vanadium Redox Flow Battery on a system level. The model is validated with experimental data from three flow battery manufacturers and is then deployed in an extensive parameter study for designing a flow battery cell. Using finite element analysis (FEA), twenty-four different cell designs are derived, which vary in electrode area and the design of the electrolyte inlet and outlet supply channels. The performance of the designs is then simulated in a single-stack and a three-stack string system. The presented model is also deployed in a flow rate optimization study. Here, a novel strategy involving the model-based optimization of operation-points defined by state-of-charge and charging or discharging current is presented and compared to conventional flow rate control strategies. Finally, a stack voltage controller is introduced, which prevents the violation of cell voltage limits as long as the pump capacity is not fully utilized.

Dieser Download kann aus rechtlichen Gründen nur mit Rechnungsadresse in A, B, BG, CY, CZ, D, DK, EW, E, FIN, F, GR, HR, H, IRL, I, LT, L, LR, M, NL, PL, P, R, S, SLO, SK ausgeliefert werden.